ZHCSJO5D April 2020 – April 2021 DRV8889-Q1
PRODUCTION DATA
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|
| 電源電壓(VM、DVDD、VSDO) | ||||||
| IVM | VM 工作電源電流 | DRVOFF = 0、nSLEEP = 1,無輸出 | 5 | 7 | mA | |
| IVMQ | VM 睡眠模式電源電流 | nSLEEP = 0 | 2 | 4 | μA | |
| tSLEEP | 休眠時間 | nSLEEP = 0 至睡眠模式 | 75 | μs | ||
| tRESET | nSLEEP 復位脈沖 | nSLEEP 低電平至僅清除故障寄存器 | 18 | 35 | μs | |
| tWAKE | 喚醒時間 | DRV8889-Q1,nSLEEP = 1 至輸出轉換 | 0.6 | 0.9 | ms | |
| DRV8889A-Q1,nSLEEP = 1 至 SPI 就緒 | 100 | 200 | μs | |||
| tON | 開通時間 | DRV8889-Q1,VM > UVLO 至輸出轉換 | 0.6 | 0.9 | ms | |
| DRV8889A-Q1,SPI 就緒,VM > UVLO 至輸出轉換 | 0.4 | 0.9 | ms | |||
| VDVDD | 內部穩壓器電壓 | 無外部負載,6V < VVM < 45V | 4.5 | 5 | 5.5 | V |
| 電荷泵(VCP、CPH、CPL) | ||||||
| VVCP | VCP 工作電壓 | VM + 5 | V | |||
| f(VCP) | 電荷泵開關頻率 | VVM > UVLO;nSLEEP = 1 | 400 | kHz | ||
| 邏輯電平輸入(STEP、DIR、nSLEEP、nSCS、SCLK、SDI、DRVOFF) | ||||||
| VIL | 輸入邏輯低電平電壓 | 0 | 0.6 | V | ||
| VIH | 輸入邏輯高電平電壓 | 1.5 | 5.5 | V | ||
| VHYS | 輸入邏輯遲滯 | 150 | mV | |||
| IIL1 | 輸入邏輯低電平電流 | VIN = 0V(nSCS、DRVOFF) | 8 | 12 | μA | |
| IIL2 | 輸入邏輯低電平電流 | VIN = 0V | -1 | 1 | μA | |
| IIH1 | 輸入邏輯高電平電流 | VIN = DVDD(nSCS、DRVOFF) | 500 | nA | ||
| IIH2 | 輸入邏輯高電平電流 | VIN = 5V | 50 | μA | ||
| 推挽式輸出 (SDO) | ||||||
| RPD,SDO | 內部下拉電阻 | 5mA 負載,以 GND 為基準 | 40 | 75 | ? | |
| RPU,SDO | 內部上拉電阻 | 5mA 負載,以 VSDO 為基準 | 30 | 60 | ? | |
| ISDO | SDO 泄漏電流 | SDO = VSDO 和 0V | -1 | 1 | μA | |
| 控制輸出 (nFAULT) | ||||||
| VOL | 輸出邏輯低電平電壓 | IO = 5mA | 0.4 | V | ||
| IOH | 輸出邏輯高電平泄漏電流 | VVM = 13.5V | -1 | 1 | μA | |
| 電機驅動器輸出(AOUT1、AOUT2、BOUT1、BOUT2) | ||||||
| RDS(ONH) | 高側 FET 導通電阻 | TJ = 25°C,IO = -1A | 450 | 550 | m? | |
| TJ = 125°C,IO = -1A | 700 | 850 | m? | |||
| TJ = 150°C,IO = -1A | 780 | 950 | m? | |||
| RDS(ONL) | 低側 FET 導通電阻 | TJ = 25°C,IO = 1A | 450 | 550 | m? | |
| TJ = 125°C,IO = 1A | 700 | 850 | m? | |||
| TJ = 150°C,IO = 1A | 780 | 950 | m? | |||
| tSR | 輸出壓擺率 | SR = 00b,VM = 13.5V,IO = 0.5A | 10 | V/μs | ||
| SR = 01b,VM = 13.5V,IO = 0.5A | 35 | |||||
| SR = 10b,VM = 13.5V,IO = 0.5A | 50 | |||||
| SR = 11b,VM = 13.5V,IO = 0.5A | 105 | |||||
| PWM 電流控制 (VREF) | ||||||
| KV | 跨阻增益 | 2.2 | V/A | |||
| tOFF | PWM 關斷時間 | TOFF = 00b | 7 | μs | ||
| TOFF = 01b | 16 | |||||
| TOFF = 10b | 24 | |||||
| TOFF = 11b | 32 | |||||
| ΔITRIP | 電流跳變精度 | IO = 1.5A,10% 至 20% 電流設置 | –13 | 10 | % | |
| IO = 1.5A,20% 至 67% 電流設置 | –8 | 8 | ||||
| IO = 1.5A,67% 至 100% 電流設置 | –7.5 | 7.5 | ||||
| IO,CH | AOUT 和 BOUT 電流匹配 | IO = 1.5A | -2.5 | 2.5 | % | |
| 保護電路 | ||||||
| VUVLO | VM UVLO 鎖定 | VM 下降,UVLO 下降 | 4.15 | 4.25 | 4.35 | V |
| VM 上升,UVLO 上升 | 4.25 | 4.35 | 4.45 | |||
| VUVLO,HYS | 欠壓遲滯 | 上升至下降閾值 | 100 | mV | ||
| VRST | VM UVLO 復位 | VM 下降,器件復位,無SPI 通信 | 3.9 | V | ||
| VCPUV | 電荷泵欠壓 | VCP 下降;CPUV 報告 | VM + 2 | V | ||
| IOCP | 過流保護 | 流經任何 FET 的電流 | 2.4 | A | ||
| tOCP | 過流抗尖峰時間 | VVM < 37V | 3 | μs | ||
| VVM ≥ 37 V | 0.5 | |||||
| tRETRY | 過流重試時間 | OCP_MODE = 1b | 4 | ms | ||
| tOL | 開路負載檢測時間 | DRV8889-Q1,EN_OL = 1b | 200 | ms | ||
| DRV8889A-Q1,EN_OL = 1b,OL_TIME = 00b | 200 | |||||
| DRV8889A-Q1,EN_OL = 1b,OL_TIME = 01b | 125 | |||||
| DRV8889A-Q1,EN_OL = 1b,OL_TIME = 10b | 75 | |||||
| DRV8889A-Q1,EN_OL = 1b,OL_TIME = 11b | 3 | |||||
| IOL | 開路負載電流閾值 | 30 | mA | |||
| TOTW | 過熱警告 | 內核溫度 TJ | 135 | 150 | 165 | °C |
| TUTW | 欠溫警告 | 內核溫度 TJ | -25 | -10 | 5 | °C |
| TOTSD | 熱關斷 | 內核溫度 TJ | 150 | 165 | 180 | °C |
| THYS_OTSD | 熱關斷遲滯 | 內核溫度 TJ | 20 | °C | ||
| THYS_OTW | 過熱警告遲滯 | 內核溫度 TJ | 20 | °C | ||
| THYS_UTW | 欠溫警告遲滯 | 內核溫度 TJ | 10 | °C | ||