ZHCSN22 April 2020 DRV8434S
PRODUCTION DATA
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|
| 電源電壓(VM、DVDD) | ||||||
| IVM | VM 工作電源電流 | ENABLE = 1,nSLEEP = 1,無電機負載 | 5 | 6.5 | mA | |
| IVMQ | VM 睡眠模式電源電流 | nSLEEP = 0 | 2 | 4 | μA | |
| tSLEEP | 休眠時間 | nSLEEP = 0 至睡眠模式 |
120 | μs | ||
| tRESET | nSLEEP 復位脈沖 | nSLEEP 低電平至清除故障 |
20 |
40 | μs | |
| tWAKE | 喚醒時間 | nSLEEP = 1 至輸出轉換 | 0.8 | 1.2 | ms | |
| tON | 開通時間 | VM > UVLO 至輸出轉換 | 0.8 | 1.2 | ms | |
|
tEN |
啟用時間 |
ENABLE = 0/1 至輸出轉換 |
5 | μs | ||
| VDVDD | 內部穩壓器電壓 | 無外部負載, 6V < VVM < 48V | 4.75 | 5 | 5.25 | V |
| 無外部負載, VVM = 4.5V |
4.2 |
4.35 |
V | |||
| 電荷泵(VCP、CPH、CPL) | ||||||
| VVCP | VCP 工作電壓 | 6V < VVM < 48V | VVM + 5 | V | ||
| f(VCP) | 電荷泵開關頻率 | VVM > UVLO;nSLEEP = 1 | 360 | kHz | ||
| 邏輯電平輸入(STEP、DIR、nSLEEP、nSCS、SCLK、SDI、ENABLE) | ||||||
| VIL | 輸入邏輯低電平電壓 | 0 | 0.6 | V | ||
| VIH | 輸入邏輯高電平電壓 | 1.5 | 5.5 | V | ||
| VHYS | 輸入邏輯遲滯 | 150 | mV | |||
| IIL1 | 輸入邏輯低電平電流 (nSCS) | VIN = 0V | 8 | 12 | μA | |
| IIL | 輸入邏輯低電平電流(其他引腳) | VIN = 0V | -1 | 1 | μA | |
| IIH1 | 輸入邏輯高電平電流 (nSCS) | VIN = DVDD | 500 | nA | ||
| IIH | 輸入邏輯高電平電流(其他引腳) | VIN = 5V | 100 | μA | ||
| 推挽式輸出 (SDO) | ||||||
| RPD,SDO | 內部下拉電阻 | 5mA 負載,以 GND 為基準 | 30 | 60 | ? | |
| RPU,SDO | 內部上拉電阻 | 5mA 負載,以 VSDO 為基準 | 30 | 60 | ? | |
| ISDO | SDO 泄漏電流 | SDO = VSDO 和 0V | -1 | 1 | μA | |
| 控制輸出 (nFAULT) | ||||||
| VOL | 輸出邏輯低電平電壓 | IO = 5mA | 0.5 | V | ||
| IOH | 輸出邏輯高電平泄漏電流 | -1 | 1 | μA | ||
| 電機驅動器輸出(AOUT1、AOUT2、BOUT1、BOUT2) | ||||||
| RDS(ON) | 高側 FET 導通電阻 | TJ = 25°C、IO = -1A | 165 | 200 | m? | |
| TJ = 125°C、IO = -1A | 250 | 300 | m? | |||
| TJ = 150°C、IO = -1A | 280 | 350 | m? | |||
| RDS(ON) | 低側 FET 導通電阻 | TJ = 25°C、IO = 1A | 165 | 200 | m? | |
| TJ = 125°C、IO = 1A | 250 | 300 | m? | |||
| TJ = 150°C、IO = 1A | 280 | 350 | m? | |||
| tSR | 輸出壓擺率 | VVM = 24V、IO = 1A,在 10% 至 90% 之間 | 240 | V/μs | ||
| PWM 電流控制 (VREF) | ||||||
| KV | 跨阻增益 | VREF = 3.3V | 1.254 | 1.32 | 1.386 | V/A |
|
IVREF |
VREF 泄漏電流 | VREF = 3.3V |
8.25 | μA | ||
| tOFF | PWM 關斷時間 | TOFF = 00b | 7 | μs | ||
| TOFF = 01b | 16 | |||||
| TOFF = 10b | 24 | |||||
| TOFF = 11b | 32 | |||||
| ΔITRIP | 電流跳變精度 | 0.25A < IO < 0.5A | –12 | 12 | % | |
| 0.5A < IO < 1A | -6 |
6 | ||||
| 1A < IO < 2.5A | -4 |
4 | ||||
| IO,CH | AOUT 和 BOUT 電流匹配 | IO = 2.5A | -2.5 | 2.5 | % | |
| 保護電路 | ||||||
| VUVLO | VM UVLO 鎖定 | VM 下降,UVLO 下降 | 4.1 | 4.25 | 4.35 | V |
| VM 上升,UVLO 上升 | 4.2 | 4.35 | 4.45 | |||
| VUVLO,HYS | 欠壓遲滯 | 上升至下降閾值 | 100 | mV | ||
| VRST | VM UVLO 復位 | VM 下降,器件復位,SPI 通信 | 3.9 | V | ||
| VCPUV | 電荷泵欠壓 | VCP 下降;CPUV 報告 | VVM + 2 | V | ||
| IOCP | 過流保護 | 流經任何 FET 的電流 | 4 | A | ||
| tOCP | 過流抗尖峰時間 | 2 | μs | |||
| tRETRY | 過流重試時間 | OCP_MODE = 1b | 4 | ms | ||
| tOL | 開路負載檢測時間 | EN_OL = 1b | 50 | ms | ||
| IOL | 開路負載電流閾值 | EN_OL = 1b | 75 | mA | ||
| TOTW | 過熱警告 | 內核溫度 TJ | 135 | 150 | 165 | °C |
| TOTSD | 熱關斷 | 內核溫度 TJ | 150 | 165 | 180 | °C |
| THYS_OTSD | 熱關斷遲滯 | 內核溫度 TJ | 20 | °C | ||
| THYS_OTW | 過熱警告遲滯 | 內核溫度 TJ | 20 | °C | ||