SNLS779A July 2025 – November 2025 DP83TC815-Q1
PRODUCTION DATA
The PTP Time Read or Write is done using the same register PTP_TDR. Since the time value is 62 bits, the register needs to be read/written 4 times to access the whole time value. The Setting time through the PTP Time Data Register involves writing all four time fields to the PTP_TDR and then issuing a 'Load PTP Clock' command through the PTP Control Register. The Time value can also be read using the PTP_TDR register by first setting the 'Read PTP Clock' command in the PTP Control Register and then reading all four time fields.
Writing a time value requires the following steps in the same order
Read a time value requires the following steps in the same order