SLVSBD1B December 2012 – August 2025 TPS65175
PRODUCTION DATA
The output voltage of the positive charge pump is programmable via a two-wire interface between 19 V and 34 V with a 4-bit resolution for VGH_LT, and between 17 V and 32 V with a 4-bit resolution for VGH_HT. See the Appendix section to set the VGH_LT and VGH_HT voltage.
In the case where VGH_LT ≤ VGH_HT, whatever the temperature is, the output voltage will be VGH_HT.