ZHCSFY3B November 2016 – February 2019 TAS2559
PRODUCTION DATA.
Sticky register used to indicate the source of an interrupt trigger. Register is cleared once read.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Reserved | Reserved | Reserved | Reserved | INT_CLK1 | INT_CLK2 | Reserved | Reserved |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | Reserved | R | 0h | Reserved |
| 6 | Reserved | R | 0h | Reserved |
| 5 | Reserved | R | 0h | Reserved |
| 4 | Reserved | R | 0h | Reserved |
| 3 | INT_CLK1 | R | 0h | Sticky bit indicating that clock error 1 condition
0 = did not occurred since last read 1 = occurred since last read |
| 2 | INT_CLK2 | R | 0h | Sticky bit indicating that the clock error 2 condition
0 = did not occurred since last read 1 = occurred since last read |
| 1 | Reserved | R | 0h | Reserved |
| 0 | Reserved | R | 0h | Reserved |