ZHCSCK8H May 2014 – April 2025 LP8860-Q1
PRODUCTION DATA
Sloper makes the smooth transition from one brightness value to another. Slope time can be programmed with EEPROM bits <PWM_SLOPE[2:0]> from 0 to 511 ms. Slope time is used for sloping up and down. Advanced slope makes brightness changes smooth for eye.
| PWM_SLOPE[2:0] | SLOPE TIME |
|---|---|
| 000 | disabled |
| 001 | 1 ms |
| 010 | 2 ms |
| 011 | 52 ms |
| 100 | 105 ms |
| 101 | 210 ms |
| 110 | 315 ms |
| 111 | 511 ms |
Figure 6-6 Sloper Operation