ZHCSF47E June 2016 – December 2017 TAS2560
PRODUCTION DATA.
Sets if the device will try to auto
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Reserved | CLK_ERR2_AR | CLK_ERR1_AR | Reserved | ||||
| RW-0h | RW-0h | RW-0h | RW-0h | ||||
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-4 | Reserved | RW | 0h | Reserved |
| 3 | CLK_ERR2_AR | RW | 0h | When an error occurs on clock error 2 block the device will
0 = perform a recovery when condition clears 1 = will shutdown and require user recovery |
| 2 | CLK_ERR1_AR | RW | 0h | When an error occurs on clock error 1 block the device will
0 = perform a recovery when condition clears 1 = will shutdown and require user recovery |
| 1-0 | Reserved | RW | 0h | Reserved |