ZHCSF68D May 2015 – July 2019 DRV8305-Q1
PRODUCTION DATA.
| BIT | R/W | NAME | DEFAULT | DESCRIPTION |
|---|---|---|---|---|
| 10 | R | FAULT | 0x0 | Fault indication |
| 9 | R | RSVD | 0x0 | - |
| 8 | R | TEMP_FLAG4 | 0x0 | Temperature flag setting for approximately 175°C |
| 7 | R | PVDD_UVFL | 0x0 | PVDD undervoltage flag warning |
| 6 | R | PVDD_OVFL | 0x0 | PVDD overvoltage flag warning |
| 5 | R | VDS_STATUS | 0x0 | Real time OR of all VDS overcurrent monitors |
| 4 | R | VCHP_UVFL | 0x0 | Charge pump undervoltage flag warning |
| 3 | R | TEMP_FLAG1 | 0x0 | Temperature flag setting for approximately 105°C |
| 2 | R | TEMP_FLAG2 | 0x0 | Temperature flag setting for approximately 125°C |
| 1 | R | TEMP_FLAG3 | 0x0 | Temperature flag setting for approximately 135°C |
| 0 | R | OTW | 0x0 | Overtemperature warning |