SPRS841E March 2012 – October 2019 TMS320C6652 , TMS320C6654
PRODUCTION DATA.
請(qǐng)參考 PDF 數(shù)據(jù)表獲取器件具體的封裝圖。
The JTAG ID register is a read-only register that identifies to the customer the JTAG/Device ID. For the device, the JTAG ID register resides at address location 0x0262 0018. The JTAG ID Register is shown in Figure 8-3 and described in Table 8-5.
| 31 | 28 | 27 | 12 | 11 | 1 | 0 |
| VARIANT | PART NUMBER | MANUFACTURER | LSB | ||||||||||||
| R-xxxxb | R-1011 1001 0111 1010b | 0000 0010 111b | R-1 | ||||||||||||
| Legend: RW = Read/Write; R = Read only; -n = value after reset |
| BIT | FIELD | VALUE | DESCRIPTION |
|---|---|---|---|
| 31-28 | VARIANT | xxxxb | Variant (4-Bit) value. |
| 27-12 | PART NUMBER | 1011 1001 0111 1010b | Part Number for boundary scan |
| 11-1 | MANUFACTURER | 0000 0010 111b | Manufacturer |
| 0 | LSB | 1b | This bit is read as a 1 for C6654 and C6652 |
NOTE
The value of the VARIANT and PART NUMBER fields depend on the silicon revision. See the Silicon Errata for details.