ZHCSSV5 January 2024 TMP119
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |||
|---|---|---|---|---|---|---|---|---|
| TEMPERATURE TO DIGITAL CONVERTER | ||||||||
| Temperature accuracy | TMP119 | 0°C to 45°C | 8 averages 1-Hz conversion cycle I2C Input voltages: VIL ≤ 0.05 * V+, VIH ≥ 0.95 * V+ |
–0.08 | ±0.03 | 0.08 | °C | |
| –25°C to 85°C | –0.09 | ±0.03 | 0.09 | |||||
| –40°C to 85°C | –0.12 | ±0.06 | 0.12 | |||||
| –55°C to 125°C | –0.15 | ±0.06 | 0.15 | |||||
| –55°C to 150°C | –0.2 | ±0.06 | 0.2 | |||||
| TMP119M | 0°C to 45°C | –0.08 | ±0.03 | 0.08 | ||||
| –20°C to 65°C | –0.09 | ±0.03 | 0.09 | |||||
| DC power supply sensitivity | One-shot mode, 8 internal averages | 6 | m°C/V | |||||
| Response Time | Response Time | t63% step Stirred liquid 31mil thick rigid PCB |
t63% step Stirred liquid 31mil thick rigid PCB |
1 | s | |||
| Gain Error | Maximum Temp Error Drift over 10°C | –0.04 | 0.04 | °C | ||||
| Temperature resolution (LSB) | 7.8125 | m°C | ||||||
| Repeatability(1) | V+ = 3.3 V 8 averages 1-Hz conversion cycle |
±1 | LSB | |||||
| Long-term stability and drift | 1000 hours at 150°C(2) | ±0.03 | °C | |||||
| Temperature cycling and hysteresis(3) | 8 Averages | ±2 | LSB | |||||
| Conversion time | No internal averages | 13 | 15.5 | 17.5 | ms | |||
| DIGITAL INPUT/OUTPUT | ||||||||
| Input capacitance | 4 | pF | ||||||
| VIH | Input logic high level | SCL, SDA, ADD0 | 0.7 * (V+) | V | ||||
| VIL | Input logic low level | SCL, SDA, ADD0 | 0.3 * (V+) | V | ||||
| IIN | Input leakage current | –0.1 | 0.1 | μA | ||||
| VOL | SDA and ALERT output logic low level | IOL = –3mA | 0.4 | V | ||||
| POWER SUPPLY | ||||||||
| IQ_ACTIVE | Quiescent current during active conversion | Active Conversion, serial bus inactive | 135 | 220 | μA | |||
| IQ | Quiescent current | Duty cycle 1Hz, averaging mode off, serial bus inactive. TA = 25°C | 3.5 | 5 | μA | |||
| Duty cycle 1Hz, 8 averaging mode on, serial bus inactive. TA = 25°C | 16 | 22 | ||||||
| Duty cycle 1Hz, averaging mode off, serial bus active, SCL frequency = 400kHz | 15 | |||||||
| ISB | Standby current(4) | Serial bus inactive. SCL, SDA, and ADD0 = V+. TA = 25°C | 1.25 | 2 | μA | |||
| ISD | Shutdown current | Serial bus inactive, SCL, SDA, and ADD0 = V+. TA = 25°C | 0.15 | 0.35 | μA | |||
| Shutdown current | Serial bus inactive, SCL, SDA and ADD0 = V+, TA = 150°C | 5 | μA | |||||
| Shutdown current | Serial bus active, SCL frequency = 400kHz, ADD0 = V+ | 17 | μA | |||||
| IEE | EEPROM write quiescent current | ADC conversion off; serial bus inactive | 240 | μA | ||||
| VPOR | Power-on-reset threshold voltage | Supply rising | 1.6 | V | ||||
| Brownout detect | Supply falling | 1.1 | V | |||||
| tRESET | Reset Time | Time required by device to reset | 1.5 | ms | ||||