| SHELFV (Bit
15): SHELF mode triggered through low cell voltage |
| 1 = | Active |
| 0 = | Inactive |
|
| SHIPM (Bit
14): SHIP mode triggered through command |
| 1 = | Active |
| 0 = | Inactive |
|
| RSVD (Bits
13–11): Reserved |
|
| SLPAD (Bit
10): ADC measurement in SLEEP, SHIP, or SHELF mode |
| 1 = | Active |
| 0 = | Inactive |
| | |
| RSVD (Bit
9): Reserved |
| | |
| INIT (Bit
8): Initialization after full reset |
| 1 = | Active |
| 0 = | Inactive |
| | |
| SHELFM (Bit
7): SHELF mode triggered through command |
| 1 = | Active |
| 0 = | Inactive |
| | |
| XL (Bit 6):
400-kHz mode |
| 1 = | Active |
| 0 = | Inactive |
| | |
| RSVD (Bit
5): Reserved |
| | |
| CAL (Bit
4): Calibration output (raw ADC and CC data) |
| 1 = | Active when either the MAC
OutputCCADCCal() or OutputShortedCCADCCal() is
sent and the raw CC and ADC data for calibration is
available. |
| 0 = | When the raw CC and ADC data
for calibration is not available. |
| | |
| RSVD (Bit
3): Reserved |
| | |
| AUTH (Bit
2): Authentication in progress |
| 1 = | Active |
| 0 = | Inactive |
| | |
| RSVD (Bit
1): Reserved |
| | |
| SDM (Bit
0): SHUTDOWN mode triggered through command |
| 1 = | Active |
| 0 = | Inactive |