SLUUD50 October 2024 BQ27Z758
The device has a hardware-based cell undervoltage protection with adjustable threshold and delay time.
| Status | Condition | Action |
|---|---|---|
| Normal | Voltage() > Protector UVP Threshold | SafetyStatus()[HCUV] = 0 |
| Trip | Voltage() ≤ Protector UVP Threshold for Protector UVP Delay Time | SafetyStatus()[HCUV] = 1 OperationStatus()[XDSG] = 1 Turn off DSG FET |
| Recovery | SafetyStatus()[HCUV] = 1 AND (Voltage() ≥HCUV:Recovery for HCUV:Recovery Delay in RELAX or DISCHARGE mode) OR (Voltage() ≥ HCUV:Recovery Chg for HCUV:Recovery Delay in CHARGE mode) | SafetyStatus()[HCUV] = 0 OperationStatus()[XDSG] = 0 |