SLUUCO9A April 2023 – November 2023 BQ28Z620
This command enables or disables the gauging function to ease testing during manufacturing.
| Status | Condition | Action |
|---|---|---|
| Disable | ManufacturingStatus()[Gauge] = 1 AND 0x0021 to MACSubcmd() | ManufacturingStatus()[Gauge] = 0 Disables gauging feature |
| Enable | ManufacturingStatus()[Gauge] = 0 AND 0x0021 to MACSubcmd() | ManufacturingStatus()[Gauge] = 1 Enable gauging feature |