The device has an undertemperature protection for cells in charge direction.
| Status | Condition | Action |
|---|---|---|
| Normal | Temperatures() > UTC:Threshold OR not charging | SafetyAlert()[UTC] = 0 |
| Alert | Temperatures() ≤ UTC:Threshold AND charging | SafetyAlert()[UTC] = 1 |
| Trip | Temperatures() ≤ UTC:Threshold AND charging for UTC:Delay duration | SafetyAlert()[UTC] = 0 SafetyStatus()[UTC] = 1 OperationStatus()[XCHG] = 1 |