ZHCSXI1B May 2024 – February 2025 TLV1831 , TLV1832 , TLV1841 , TLV1842
PRODMIX
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|
| 失調電壓 | ||||||
| VOS | 輸入失調電壓 | TA = 25°C | -2.5 | ±0.3 | 2.5 | mV |
| TA = -40°C 至 +125°C | -3.0 | 3.0 | mV | |||
| dVIO/dT | 輸入偏移電壓漂移 | TA = -40°C 至 +125°C | ±1.2 | μV/°C | ||
| 電源 | ||||||
| IQ | 每個比較器的靜態電流, 僅 TLV18x1 |
無負載,輸出高電平 TA = 25°C TLV1831、TLV1841 |
75 | 100 | μA | |
| 無負載,輸出高電平 TA = –40°C 至 +125°C TLV1831、TLV1841 |
105 | μA | ||||
| 無負載,輸出低電平 TA = 25°C TLV1831、TLV1841 |
100 | 135 | μA | |||
| 無負載,輸出低電平 TA = –40°C 至 +125°C TLV1831、TLV1841 |
140 | μA | ||||
| IQ | 靜態電流(每個比較器) | 無負載,輸出高電平 TA = 25°C | 75 | 95 | μA | |
| 無負載,輸出高電平 TA = –40°C 至 +125°C | 100 | μA | ||||
| 無負載,輸出低電平 TA = 25°C | 95 | 130 | μA | |||
| 無負載,輸出低電平 TA = –40°C 至 +125°C | 135 | μA | ||||
| VPOR | 1.9 | V | ||||
| 輸入偏置電流 | ||||||
| IB | 輸入偏置電流(1) | 500 | pA | |||
| IB | 輸入偏置電流 (1) (2) | TA = -40°C 至 +125°C | -5 | 5 | nA | |
| IOS | 輸入失調電流 | 10 | pA | |||
| 輸入電容 | ||||||
| CID | 輸入電容,差分 | 5 | pF | |||
| CIC | 輸入電容,共模 | 5 | pF | |||
| 輸入共模范圍 | ||||||
| VCM-Range | 共模電壓范圍 | VS = 2.7V 至 40V TA = -40°C 至 +125°C |
(V–) – 0.2 | (V+) + 0.2 | V | |
| 輸出 | ||||||
| VOL | (V–) 的電壓擺幅 | ISINK = 4mA TA = -40°C 至 +125°C |
400 | mV | ||
| VOH | (V+) 的電壓擺幅(僅適用于推挽) | ISOURCE = 4mA TA = -40°C 至 +125°C |
400 | mV | ||
| ILKG | 開漏輸出漏電流 | VID = +0.1V,VPULLUP = (V+) TA = -40°C 至 +125°C |
3 | 70 | nA | |
| IOL | 短路電流 | 灌電流 TA = –40°C 至 +125°C |
30 | mA | ||
| IOH | 短路電流 | 拉電流 TA = –40°C 至 +125°C |
30 | mA | ||