ZHCSHK8E october 2017 – july 2023 TAS2770
PRODUCTION DATA
Sets PDM capture edge, master/slave, clock source and gating.
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| PDM_EDGE1 | Reserved | PDM_SLV1 | Reserved | PDM_CLK1 | Reserved | PDM_GATE1 | Reserved |
| RW-0h | RW-0h | RW-0h | RW-0h | RW-1h | RW-0h | RW-0h | RW-0h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | PDM_EDGE1 | RW | 0h | PDMD1 input capture edge. 0b = Rising 1b = Falling |
| 6 | Reserved | RW | 0h | Reserved |
| 5 | PDM_SLV1 | RW | 0h | PDMD1 input master or slave. 0b = Slave 1b = Master |
| 4 | Reserved | RW | 0h | Reserved |
| 3 | PDM_CLK1 | RW | 1h | PDMD1 clock select. 0b = GND 1b = PDMCK1 |
| 2 | Reserved | RW | 0h | Reserved |
| 1 | PDM_GATE1 | RW | 0h | PDMD1 clock gate. 0b = Gated Off 1b = Active |
| 0 | Reserved | RW | 0h | Reserved |