| VALUE | UNIT |
|---|
| V(ESD) | Electrostatic discharge(3) | Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) | ±2000 | V |
| Charged-device model (CDM), per JEDEC specification JESD22-C101(2) | ±500 |
(1) JEDEC document JEP155 states that 500V HBM allows safe manufacturing with a
standard ESD control process.
(2) JEDEC document JEP157 states that 250V CDM allows safe manufacturing with a
standard ESD control process
(3) The human-body model is a 100pF capacitor discharged through a 1.5k? resistor
into each pin.