over operating free-air temperature range (unless otherwise noted)(1) (2) (3) | MIN | MAX | UNIT |
|---|
| VMX | Power supply voltage | –0.3 | 35 | V |
| VCC | Power supply voltage | –0.3 | 7 | V |
| Digital pin voltage | –0.5 | 7 | V |
| VREF | Input voltage | 0 | VCC | V |
| ISENSEx(4) | Pin voltage | –0.875 | 0.875 | V |
| IO(peak) | Peak motor drive output current | Internally limited | |
| PD | Continuous total power dissipation | See Section 5.4 | |
| TJ | Operating junction temperature | –40 | 150 | °C |
| Tstg | Storage temperature | –60 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings can cause
permanent damage to the device. These are stress ratings only, and functional operation of
the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions
for extended periods can affect device reliability.
(2) All voltage values are with respect to network ground terminal.
(3) Power dissipation and thermal limits must be observed.
(4) Transients of ±1V for less than 25ns are acceptable.