SLVUAW9C September 2016 – February 2020 UCD90320
This Read Block common command provides fixed information about the device.
| Byte Number
(Write) |
Byte Number
(Read) |
Payload
Index |
Description |
|---|---|---|---|
| 0 | CMD = DF | ||
| 1 | 0 | BYTE_COUNT = 8 | |
| 2 | 1 | 0 | Maximum Number of Digital Comparators |
| 3 | 2 | 1 | Maximum Number of General-Purpose Outputs (GPOs) |
| 4 | 3 | 2 | Maximum Number of General-Purpose Inputs (GPIs) |
| 5 | 4 | 3 | Maximum Number of Pages |
| 6 | 5 | 4 | Maximum Number of Fans |
| 7 | 6 | 5 | Maximum Number of Monitors |
| 8 | 7 | 6 | Maximum Number of Entries in the Logged Fault Detail (see Section 10.26) |
| 9 | 8 | 7 | Maximum Number of PWM outputs |
| Constant | 90120 | 90120A | 90124 | 90124A | 9090 | 90160 | 90910 | 90240 | 90320 |
|---|---|---|---|---|---|---|---|---|---|
| Digital Comparators | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 0 | 0 |
| GPOs | 12 | 12 | 12 | 12 | 10 | 16 | 10 | 12 | 16 |
| GPIs | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 24 | 32 |
| Pages | 12 | 12 | 12 | 12 | 10 | 16 | 10 | 24 | 32 |
| Fans | 0 | 0 | 4 | 4 | 0 | 0 | 10 | 0 | 0 |
| Monitors | 13 | 13 | 13 | 13 | 11 | 16 | 13 | 24 | 32 |
| Logged Fault Detail Entries | 16 | 16 | 10 | 12 | 30 | 18 | 12 | 100 | 100 |
| PWM outputs | 12 | 12 | 12 | 12 | 10 | 12 | 12 | 24 | 24 |