Over operating free-air temperature range (unless otherwise noted), all voltages are with respect to VSS (unless otherwise noted), currents are positive into and negative out of the specified terminal.(1)
| PARAMETER |
MIN |
MAX |
UNIT |
| VHI, VLI |
Input voltages on HI and LI(2) |
–0.3 |
23 |
V |
| VDD |
VDD supply voltage |
–0.3 |
23 |
| VHB |
Voltage on HB |
–0.3 |
230 |
| VHB–VHS |
Bootstrap supply voltage |
–0.3 |
23 |
| VHO |
Output voltage on HO |
DC |
HS–0.3 |
HB+0.3 |
V |
| Transient, less than 100 ns(3) |
HS–2 |
HB+0.3 |
| VLO |
Output voltage on LO |
DC |
–0.3 |
VDD+0.3 |
V |
| Transient, less than 100 ns(3) |
–2 |
VDD+0.3 |
| VHS |
Voltage on HS |
DC |
–18(4) |
230 |
V |
| Transient, less than 100 ns(3) |
–23(4) |
230 |
V |
| dVHS/dt |
Allowable offset supply voltage transient |
–100 |
100 |
V/ns |
| TJ |
Junction temperature |
–40 |
150 |
°C |
| Tstg |
Storage temperature |
–65 |
150 |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The maximum voltage on the input pins is not restricted by the voltage on the VDD pin.
(3) Values are verified by characterization on bench.
(4) At HB–HS = 15 V.