6.3 Recommended Operating Conditions
|
|
MIN |
MAX |
UNIT |
| VIN1,2 |
Input voltage range |
0 |
VBIAS |
V |
| VBIAS |
Bias voltage range |
2.5 |
5.5 |
V |
| VON1,2 |
ON voltage range |
0 |
5.5 |
V |
| VOUT1,2 |
Output voltage range |
|
VIN |
V |
| VIH |
High-level input voltage, ON |
VBIAS = 2.5 V to 5.5 V |
1.2 |
5.5 |
V |
| VIL |
Low-level input voltage, ON |
VBIAS = 2.5 V to 5.5 V |
0 |
0.5 |
V |
| CIN1,2 |
Input capacitor |
1(1) |
|
µF |
| TA |
Operating free-air temperature(2) |
–40 |
105 |
°C |
(2) In applications where high power dissipation and/or poor package thermal resistance is present, the maximum ambient temperature may have to be derated. Maximum ambient temperature [TA(max)] is dependent on the maximum operating junction temperature [TJ(max)], the maximum power dissipation of the device in the application [PD(max)], and the junction-to-ambient thermal resistance of the part/package in the application (θJA), as given by the following equation: TA(max) = TJ(max) – (θJA × PD(max))