ZHCSMJ5F june 2010 – december 2020 TLV809
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |||
|---|---|---|---|---|---|---|---|---|
| VOH | High-level output voltage | VDD = 2.5 V to 6 V, IOH = –500 μA | VDD – 0.2 | V | ||||
| VDD = 3.3 V, IOH = –2 mA | VDD – 0.4 | |||||||
| VDD = 6 V, IOH = –4 mA | VDD – 0.4 | |||||||
| VOL | Low-level output voltage | VDD = 2 V to 6 V, IOH = 500 μA | 0.3 | V | ||||
| VDD = 3.3 V, IOH = 2 mA | 0.4 | |||||||
| VDD = 6 V, IOH = 4 mA | 0.4 | |||||||
| Power-up reset voltage(1) | VDD ≥ 1.1 V, IOL = 50 μA | 0.2 | V | |||||
| VIT– | Negative-going input threshold voltage(2) | TLV809J25 | TA = –40°C to +85°C | 2.20 | 2.25 | 2.30 | V | |
| TLV809L30 | 2.58 | 2.64 | 2.70 | |||||
| TLV809K33 | 2.87 | 2.93 | 2.99 | |||||
| TLV809I50 | 4.45 | 4.55 | 4.65 | |||||
| Vhys | Hysteresis | TLV809J25 | 30 | mV | ||||
| TLV809L30 | 35 | |||||||
| TLV809K33 | 40 | |||||||
| TLV809I50 | 60 | |||||||
| IDD | Supply current | VDD = 2 V, RESET is unconnected | 9 | 12 | μA | |||
| VDD = 6 V, RESET is unconnected | 20 | 25 | ||||||
| CI | Input capacitance | VI = 0 V to VDD | 5 | pF | ||||