ZHCSOZ3 September 2021 TLIN1024A-Q1
PRODUCTION DATA
| ESD and Surge Protection Ratings | VALUE | UNIT | ||
|---|---|---|---|---|
| V(ESD) | Electrostatic discharge, LIN, VSUP to GND(1) |
IEC 62228-2 per ISO 10605 Contact discharge R = 330 Ω, C = 150 pF |
±8000 | V |
| VTRAN | ISO 7637-2 and IEC 62228-2 per IEC 62215-3 transients according to IBEE LIN EMC test specifications (2) (LIN, VSUP to GND ) |
Pulse 1 | –100 | V |
| Pulse 2 | 75 | V | ||
| Pulse 3a | –150 | V | ||
| Pulse 3b | 100 | V | ||