ZHCSJ69A October 2018 – December 2018 TAS2562
PRODUCTION DATA.
Latched interrupt readback.
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | INT_LTCH0[7] | R | 0h | Interrupt due to limiter mute.
0b = No interrupt 1b = Interrupt |
| 6 | INT_LTCH0[6] | R | 0h | Interrupt due to limiter infinite hold.
0b = No interrupt 1b = Interrupt |
| 5 | INT_LTCH0[5] | R | 0h | Interrupt due to limiter max attenuation.
0b = No interrupt 1b = Interrupt |
| 4 | INT_LTCH0[4] | R | 0h | Interrupt due to VBAT below limiter inflection point.
0b = No interrupt 1b = Interrupt |
| 3 | INT_LTCH0[3] | R | 0h | Interrupt due to limiter active
0b = No interrupt 1b = Interrupt |
| 2 | INT_LTCH0[2] | R | 0h | Interrupt due to TDM clock error
0b = No interrupt 1b = Interrupt |
| 1 | INT_LTCH0[1] | R | 0h | Interrupt due to over current error
0b = No interrupt 1b = Interrupt |
| 0 | INT_LTCH0[0] | R | 0h | Interrupt due to over temp error
0b = No interrupt 1b = Interrupt |