ZHCSJ69A October 2018 – December 2018 TAS2562
PRODUCTION DATA.
Live interrupt readback.
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | INT_LIVE[7] | R | 0h | Interrupt due to limiter mute.
0b = No interrupt 1b = Interrupt |
| 6 | INT_LIVE[6] | R | 0h | Interrupt due to limiter infinite hold.
0b = No interrupt 1b = Interrupt |
| 5 | INT_LIVE[5] | R | 0h | Interrupt due to limiter max attenuation.
0b = No interrupt 1b = Interrupt |
| 4 | INT_LIVE[4] | R | 0h | Interrupt due to VBAT below limiter inflection point.
0b = No interrupt 1b = Interrupt |
| 3 | INT_LIVE[3] | R | 0h | Interrupt due to limiter active.
0b = No interrupt 1b = Interrupt |
| 2 | INT_LIVE[2] | R | 0h | Interrupt due to TDM clock error.
0b = No interrupt 1b = Interrupt |
| 1 | INT_LIVE[1] | R | 0h | Interrupt due to over current error.
0b = No interrupt 1b = Interrupt |
| 0 | INT_LIVE[0] | R | 0h | Interrupt due to over temp error.
0b = No interrupt 1b = Interrupt |