SNOK014 December 2024 TPS7H6005-SEP
The results show that all TPS7H6005-SEP devices were fully functional and within specification limits up to 50 krad (Si) HDR. Overall the TPS7H6005-SEP show a strong degree of hardness to TID HDR exposure levels at 50 krad (Si) under bias & unbiased conditions. Performance is measured based on the difference between pre- and post-irradiation with respect to SMD electrical minimum and maximum specification. The measurements taken post-irradiation for each sample set showed a marginal shift for most parameters at each dose level for both biased and unbiased. (see Section 3.2 for the electrical parameters). Note that test numbers are listed only for parameters tested post-TID.
See Appendix: HDR TID Report for HDR report.