ZHCSJY9B June 2019 – November 2021 TPS1HB50-Q1
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| SNS TIMING - CURRENT SENSE | ||||||
| tSNSION1 | Settling time from rising edge of DIA_EN | VEN = 5 V, VDIA_EN = 0 V to 5 V RSNS = 1 kΩ, RL ≤ 6 Ω | 40 | μs | ||
| tSNSION2 | Settling time from rising edge of EN and DIA_EN | VEN = VDIA_EN = 0 V to 5 V RSNS = 1 kΩ, RL ≤ 6 Ω | 200 | μs | ||
| tSNSION3 | Settling time from rising edge of EN | VEN = 0 V to 5 V, VDIA_EN = 5 V RSNS = 1 kΩ, RL ≤ 6 Ω | 165 | μs | ||
| tSNSIOFF1 | Settling time from falling edge of DIA_EN | VEN = 5 V, VDIA_EN = 5 V to 0 V RSNS = 1 kΩ, RL ≤ 6 Ω | 20 | μs | ||
| tSETTLEH | Settling time from rising edge of load step | VEN = 5 V, VDIA_EN = 5 V RSNS = 1 kΩ, IOUT = 1 A to 5 A | 20 | μs | ||
| tSETTLEL | Settling time from falling edge of load step | VEN = 5 V, VDIA_EN = 5 V RSNS = 1 kΩ, IOUT = 5 A to 1 A | 20 | μs | ||
| SNS TIMING - TEMPERATURE SENSE | ||||||
| tSNSTON1 | Settling time from rising edge of DIA_EN | VEN = 5 V, VDIA_EN = 0 V to 5 V RSNS = 1 kΩ | 40 | μs | ||
| tSNSTON2 | Settling time from rising edge of DIA_EN | VEN = 0 V, VDIA_EN = 0 V to 5 V RSNS = 1 kΩ | 70 | μs | ||
| tSNSTOFF | Settling time from falling edge of DIA_EN | VEN = X, VDIA_EN = 5 V to 0 V RSNS = 1 kΩ | 20 | μs | ||
| SNS TIMING - MULTIPLEXER | ||||||
| tMUX | Settling time from temperature sense to current sense | VEN = 5 V, VDIA_EN = 5 V VSEL1 = 5 V to 0 V RSNS = 1 kΩ, RL ≤ 6 Ω | 60 | μs | ||
| Settling time from current sense to temperature sense | VEN = 5 V, VDIA_EN = 5 V VSEL1 = 0 V to 5 V RSNS = 1 kΩ, RL ≤ 6 Ω | 60 | μs | |||