ZHCSD12B October 2014 – October 2024 TMP75B-Q1
PRODUCTION DATA
| 參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | ||
|---|---|---|---|---|---|---|---|
| 溫度傳感器 | |||||||
| 溫度范圍 | -40 | 125 | °C | ||||
| 溫度分辨率 | 0.0625 | °C | |||||
| 溫度精度(誤差) | TMP75BQDGKRQ1 TMP75BQDRQ1 |
-20°C 至 85°C | ±0.5 | ±2 | °C | ||
| -40°C 至 125°C | ±1 | ±3 | °C | ||||
| TMP75BTQDGKRQ1 | -40°C 至 125°C | ±0.5 | ±2 | °C | |||
| 數字輸入/輸出 | |||||||
| VIH | 高電平輸入電壓 | 0.7(VS) | VS | V | |||
| VIL | 低電平輸入電壓 | -0.3 | 0.3(VS) | V | |||
| IIN | 輸入電流 | 0V < VIN < (VS) + 0.3V | 1 | μA | |||
| VOL | 低電平輸出電壓 | VS ≥ 2V,IOUT = 3mA | 0 | 0.4 | V | ||
| VOL | VS < 2V,IOUT = 3mA | 0 | 0.2(VS) | V | |||
| ADC 分辨率 | 12 | 位 | |||||
| 轉換時間 | 單次觸發模式 | 20 | 27 | 35 | ms | ||
| 轉換模式 | CR1=0,CR0=0(默認值) | 37 | Conv/s | ||||
| CR1 = 0,CR0 = 1 | 18 | Conv/s | |||||
| CR1 = 1,CR0 = 0 | 9 | Conv/s | |||||
| CR1 = 1,CR0 = 1 | 4 | Conv/s | |||||
| 超時時間 | 38 | 54 | 70 | ms | |||
| 電源 | |||||||
| 工作電源電壓范圍 | 1.4 | 3.6 | V | ||||
| IQ | 靜態電流 | 串行總線無效,CR1 = 0,CR0 = 0(默認值) | 45 | 89 | μA | ||
| 串行總線無效,CR1 = 0,CR0 = 1 | 22 | 48 | μA | ||||
| 串行總線無效,CR1 = 1,CR0 = 0 | 12 | 30 | μA | ||||
| 串行總線無效,CR1 = 1,CR0 = 1 | 6.5 | 21 | μA | ||||
| ISD | 關斷電流 | 串行總線無效 | 0.3 | 8 | μA | ||
| 串行總線有效,SCL 頻率 = 400kHz | 10 | μA | |||||
| 串行總線有效,SCL 頻率 = 3.4MHz | 80 | μA | |||||