ZHCSJB8 February 2019 TAS6424M-Q1
PRODUCTION DATA.
The AC Load Diagnostic Control 1 register is shown in Figure 65 and described in Table 28.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH1/2 GAIN | RESERVED | CH3/4 GAIN | RESERVED | CH1 ENABLE | CH2 ENABLE | CH3 ENABLE | CH4 ENABLE |
| R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | CH1, CH2, PBTL12: GAIN | R/W | 0 |
0: Gain 1 1: Gain 4 |
| 6 | RESERVED | R/W | 0 | 0 |
| 5 | CH3, CH4, PBTL34: GAIN | R/W | 0 |
0: Gain 1 1: Gain 4 |
| 4 | RESERVED | R/W | 0 | 0 |
| 3 | CH1 ENABLE | R/W | 0 |
0: AC diagnostics disabled 1: Enable AC diagnostics |
| 2 | CH2 ENABLE | R/W | 0 |
0: AC diagnostics disabled 1: Enable AC diagnostics |
| 1 | CH3 ENABLE | R/W | 0 |
0: AC diagnostics disabled 1: Enable AC diagnostics |
| 0 | CH4 ENABLE | R/W | 0 |
0: AC diagnostics disabled 1: Enable AC diagnostics |