ZHCSJB8 February 2019 TAS6424M-Q1
PRODUCTION DATA.
The Warnings register is shown in Figure 63 and described in Table 26.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | VDD POR | OTW | OTW CH1 | OTW CH2 | OTW CH3 | OTW CH4 | |
| R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | ||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 -6 | RESERVED | 00 |
0 |
|
| 5 | VDD POR | R | 0 |
0: No VDD POR has occurred 1 VDD POR occurred |
| 4 | OTW | R | 0 |
0: No global overtemperature warning 1: Global overtemperature warning |
| 3 | OTW CH1 | R | 0 |
0: No overtemperature warning on channel 1 1: Overtemperature warning on channel 1 |
| 2 | OTW CH2 | R | 0 |
0: No overtemperature warning on channel 2 1: Overtemperature warning on channel 2 |
| 1 | OTW CH3 | R | 0 |
0: No overtemperature warning on channel 3 1: Overtemperature warning on channel 3 |
| 0 | OTW CH4 | R | 0 |
0: No overtemperature warning on channel 4 1: Overtemperature warning on channel 4 |