SNVSD24 August 2025 LP5814I
PRODUCTION DATA
The LP5814I provides instant blinking function for applications that require LED indication before controller is ready to send command. When VCC voltage is higher than VCC_UVLO and instant blinking function is not disabled (INSTABLINK_DIS = 0), the OUT0 waits 300ms blank time to start blinking. The timing is shown in Figure 7-9.
During the 300ms blank time,
While the LP5814I staying in INSTANT BLINKING mode,
Figure 7-10 shows the parameters of 1 cycle blinking pattern.
At the beginning, there is 500ms pause time before PWM starts ramping up. After the pause time, the PWM ramps up from 0 to 50% in 200ms, then keeps 50% for 1s. Next, it starts ramping down from 50% to 0 in 200ms. At last, the PWM keeps off for another 500ms pause time before the next cycle starts.
The maximum current setting for the instant blinking is 25.5mA with OUT0_DC = 0xFF, MAX_CURRENT = 0.
Figure 7-11 shows a typical application circuit that provides the instant blinking function. And there is a LED connected to OUT0.