SNVSD24 August 2025 LP5814I
PRODUCTION DATA
To get the design parameters in Section 8.2.2, the following program steps can be referred.
After VCC powering up and wait around 1ms,
After this step, the read LED is turned on.
After this step, the red LED keeps constant ON, the green LED keeps blinking with 5Hz frequency and blue LED keeps breathing in 2.4s period and white LED keeps blinking with 1Hz frequency.
| Address | Register | Set Value | Description |
|---|---|---|---|
| 1Ch | PATTERN0_PAUSE_TIME | 00h | No pause time |
| 1Dh | PATTERN0_REPEAT_TIME | 0Fh | Infinite repeat times |
| 1Eh | PATTERN0_PWM0 | FFh | PATTERN0_PWM0 = FFh |
| 1Fh | PATTERN0_PWM1 | FFh | PATTERN0_PWM1 = FFh |
| 20h | PATTERN0_PWM2 | 00h | PATTERN0_PWM2 = 0 |
| 21h | PATTERN0_PWM3 | 00h | PATTERN0_PWM3 = 0 |
| 22h | PATTERN0_PWM4 | 00h | PATTERN0_PWM4 = 0 |
| 23h | PATTERN0_SLOPER_TIME1 | 02h | PATTERN0_SLOPER_T1 = 0, PATTERN0_SLOPER_T0 = 0.1s |
| 24h | PATTERN0_SLOPER_TIME2 | 02h | PATTERN0_SLOPER_T3 = 0, PATTERN0_SLOPER_T2 = 0.1s |
| Address | Register | Set Value | Description |
|---|---|---|---|
| 25h | PATTERN1_PAUSE_TIME | 00h | No pause time |
| 26h | PATTERN1_REPEAT_TIME | 0Fh | Infinite repeat times |
| 27h | PATTERN1_PWM0 | 00h | PATTERN1_PWM0 = 0 |
| 28h | PATTERN1_PWM1 | FFh | PATTERN1_PWM1 = FFh |
| 29h | PATTERN1_PWM2 | FFh | PATTERN1_PWM2 = FFh |
| 2Ah | PATTERN1_PWM3 | 00h | PATTERN1_PWM3 = 0 |
| 2Bh | PATTERN1_PWM4 | 00h | PATTERN1_PWM4 = 0 |
| 2Ch | PATTERN1_SLOPER_TIME1 | 4Bh | PATTERN1_SLOPER_T1 = 0.2s, PATTERN1_SLOPER_T0 = 1s |
| 2Dh | PATTERN1_SLOPER_TIME2 | 4Bh | PATTERN1_SLOPER_T3 = 0.2s, PATTERN1_SLOPER_T2 = 1s |
| Address | Register | Set Value | Description |
|---|---|---|---|
| 2Eh | PATTERN2_PAUSE_TIME | 00h | No pause time |
| 2Fh | PATTERN2_REPEAT_TIME | 0Fh | Infinite repeat times |
| 30h | PATTERN2_PWM0 | 80h | PATTERN2_PWM0 = FFh |
| 31h | PATTERN2_PWM1 | 80h | PATTERN2_PWM1 = FFh |
| 32h | PATTERN2_PWM2 | 00h | PATTERN2_PWM2 = 0 |
| 33h | PATTERN2_PWM3 | 00h | PATTERN2_PWM3 = 0 |
| 34h | PATTERN2_PWM4 | 00h | PATTERN2_PWM4 = 0 |
| 35h | PATTERN2_SLOPER_TIME1 | 0Ah | PATTERN2_SLOPER_T1 = 0, PATTERN2_SLOPER_T0 = 0.5s |
| 36h | PATTERN2_SLOPER_TIME2 | 0Ah | PATTERN2_SLOPER_T3 = 0, PATTERN2_SLOPER_T2 = 0.5s |