ZHCSFE3B March 2016 – November 2017 LM5161
PRODUCTION DATA.
The LM5161 Fly-Buck application example is designed to operate from a nominal 48-V DC supply with line variations from 36-V to 72-V. This example provides a space-optimized and efficient 12-V isolated output solution with secondary load current capability from 0-A to 800 mA. The primary side remains unloaded in this application. The switching frequency is set at 300 kHz (nominal). This design achieves greater than 88% peak efficiency.
| DESIGN PARAMETER | EXAMPLE VALUE |
|---|---|
| Input voltage range | 36 V - 72 V |
| Isolated output | 12 V (+/- 10%) |
| Isolated load current range (IISO) | 0-A to 0.8-A |
| Nominal switching frequency | 300 KHz |
| Peak efficiency | ~87% |
| Operation mode | FPWM = 1 |