ZHCSTL7I February 2007 – November 2023 LM5116
PRODUCTION DATA
over operating free-air temperature range (unless otherwise noted)
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| PWM COMPARATORS | ||||||
| tHO(OFF) | Forced HO Off-time | 320 | 450 | 580 | ns | |
| tON(min) | Minimum HO On-time | VIN = 80 V, CRAMP = 50 pF | 100 | ns | ||
| CURRENT LIMIT | ||||||
| Current Limit Fault Timer | RT = 16 k?, (200 kHz), (256 clock cycles) | 1.28 | ms | |||
| LO GATE DRIVER | ||||||
| LO Rise Time | C-load = 1000 pF | 18 | ns | |||
| LO Fall Time | C-load = 1000 pF | 12 | ns | |||
| HO GATE DRIVER | ||||||
| HO Rise Time | C-load = 1000 pF | 19 | ns | |||
| HO High-side Fall Time | C-load = 1000 pF | 13 | ns | |||
| SWITCHING CHARACTERISTICS | ||||||
| LO Fall to HO Rise Delay | C-load = 0 | 75 | ns | |||
| HO Fall to LO Rise Delay | C-load = 0 | 70 | ns | |||