ZHCSFB0D June 2016 – November 2023 DRV2510-Q1
PRODUCTION DATA
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| DEV_ACTIVE [0] | STDBY [0] | DIAG_ACTIVE [0] | FAULT [0] | LOAD_SHORT [0] | LOAD_OPEN [0] | LOAD_SHORT_GND [0] | LOAD_SHORT_VDD [0] |
| RO-0 | RO-0 | RO-0 | RO-0 | RO-0 | RO-0 | RO-0 | RO-0 |
| BIT | FIELD | TYPE | DEFAULT | DESCRIPTION | |
|---|---|---|---|---|---|
| 7 | DEV_ACTIVE | RO | 0 | Shows the device status (active or shutdown). | |
| 0 | Device is shutdown. | ||||
| 1 | Device is active. | ||||
| 6 | STDBY | RO | 0 | Shows the device standby status. | |
| 0 | Device is not on standby. | ||||
| 1 | Device is on standby. | ||||
| 5 | DIAG_ACTIVE | RO | 0 | Shows the status of the diagnositcs engine. | |
| 0 | Not performing load diagnostics. | ||||
| 1 | Performing load diagnostics. | ||||
| 4 | FAULT | RO | 0 | Shows if a fault has occurred on the system. Either over-voltage, under-voltage, over-current, over-temperature. | |
| 0 | No fault has occurred. | ||||
| 1 | A fault has occurred. | ||||
| 3 | LOAD_SHORT | RO | 0 | Shows whether the output is shorted. | |
| 0 | OUT+ is not shorted to OUT-. | ||||
| 1 | OUT+ is shorted to OUT-. | ||||
| 2 | LOAD_OPEN | RO | 0 | Shows whether the output has a proper load connected. | |
| 0 | A proper load is connected between OUT+ and OUT-. | ||||
| 1 | There is an open connection between OUT+ and OUT-. | ||||
| 1 | LOAD_SHORT_GND | RO | 0 | Shows whether the output is shorted to GND. | |
| 0 | Output is not shorted to GND. | ||||
| 1 | Either OUT+ or OUT- is shorted to GND. | ||||
| 0 | LOAD_SHORT_VDD | RO | 0 | Shows whether the output is shorted to VDD. | |
| 0 | Output is not shorted to VDD. | ||||
| 1 | Either OUT+ or OUT- is shorted to VDD. | ||||