SLVUDE1 July 2025 TPS65219-Q1
| PMIC Rail | Register Address | Field Name | Value | Description |
|---|---|---|---|---|
| BUCK1 | 0x11 | BUCK1_SEQUENCE_ON_SLOT | 0x4 | slot 4 |
| BUCK2 | 0x10 | BUCK2_SEQUENCE_ON_SLOT | 0x2 | slot 2 |
| BUCK3 | 0x0F | BUCK3_SEQUENCE_ON_SLOT | 0x3 | slot 3 |
| LDO1 | 0x0E | LDO1_SEQUENCE_ON_SLOT | 0x2 | slot 2 |
| LDO2 | 0x0D | LDO2_SEQUENCE_ON_SLOT | 0x5 | slot 5 |
| LDO3 | 0x0C | LDO3_SEQUENCE_ON_SLOT | 0x2 | slot 2 |
| LDO4 | 0x0B | LDO4_SEQUENCE_ON_SLOT | 0x2 | slot 2 |
| GPO1 | 0x15 | GPO1_SEQUENCE_ON_SLOT | 0x6 | slot 6 |
| GPO2 | 0x14 | GPO2_SEQUENCE_ON_SLOT | 0x0 | slot 0 |
| GPIO | 0x13 | GPIO_SEQUENCE_ON_SLOT | 0x6 | slot 6 |
| nRSTOUT | 0x12 | nRST_SEQUENCE_ON_SLOT | 0x8 | slot 8 |
| Register Address | Field Name | Value | Description | |
|---|---|---|---|---|
| SLOT0 | 0x16 | POWER_UP_SLOT_0_DURATION | 0x3 | 10ms |
| SLOT1 | 0x16 | POWER_UP_SLOT_1_DURATION | 0x0 | 0ms |
| SLOT2 | 0x16 | POWER_UP_SLOT_2_DURATION | 0x2 | 3ms |
| SLOT3 | 0x16 | POWER_UP_SLOT_3_DURATION | 0x1 | 1.5ms |
| SLOT4 | 0x17 | POWER_UP_SLOT_4_DURATION | 0x1 | 1.5ms |
| SLOT5 | 0x17 | POWER_UP_SLOT_5_DURATION | 0x1 | 1.5ms |
| SLOT6 | 0x17 | POWER_UP_SLOT_6_DURATION | 0x3 | 10ms |
| SLOT7 | 0x17 | POWER_UP_SLOT_7_DURATION | 0x1 | 1.5ms |
| SLOT8 | 0x18 | POWER_UP_SLOT_8_DURATION | 0x3 | 10ms |
| SLOT9 | 0x18 | POWER_UP_SLOT_9_DURATION | 0x0 | 0ms |
| SLOT10 | 0x18 | POWER_UP_SLOT_10_DURATION | 0x0 | 0ms |
| SLOT11 | 0x18 | POWER_UP_SLOT_11_DURATION | 0x0 | 0ms |
| SLOT12 | 0x19 | POWER_UP_SLOT_12_DURATION | 0x0 | 0ms |
| SLOT13 | 0x19 | POWER_UP_SLOT_13_DURATION | 0x0 | 0ms |
| SLOT14 | 0x19 | POWER_UP_SLOT_14_DURATION | 0x0 | 0ms |
| SLOT15 | 0x19 | POWER_UP_SLOT_15_DURATION | 0x0 | 0ms |