SBOK073 august 2023 TRF0206-SP
PRODUCTION DATA
Table 1-1 lists the device information used in the TID LDR and HDR characterization.
| TID LDR/HDR Details: up to 100 krad(Si) | |
|---|---|
| TI Device Number | 5962R2122001VXC (TRF0206-SP) |
| Package | LCCC (FFM) |
| Technology | BICMOS |
| Quantity Tested | LDR: 52, HDR:52 |
| Lot Accept/Reject | All levels tested and passed up to 100 krad(Si) (LDR and HDR) |
| LDR Radiation Facility | Cobham RAD - Colorado Springs, CO |
| LDR Dose Level | 3 krad(Si), 10 krad(Si), 30 krad(Si), 50 krad(Si), 100 krad(Si) |
| LDR Dose Rate | 0.01 rad(Si)/s |
| LDR Radiation Source | Gammacell JLSA 81-24 Co-60 |
| HDR Radiation Facility | Texas Instruments, Dallas |
| HDR Dose Level | 3 krad(Si), 10 krad(Si), 30 krad(Si), 50 krad(Si), 100 krad(Si) |
| HDR Dose Rate | 263 rad(Si)/s |
| HDR Radiation Source | Co-60 gamma ray source |
| Irradiation Temperature | 25°C |