SLUSF25 September 2025 UCC27834
PRODMIX
請參考 PDF 數(shù)據(jù)表獲取器件具體的封裝圖。
The UCC278X4 allows constant on or constant off operation (0% and/or 100% duty cycle) as long as the VDD and VHB bias supplies are maintained above the UVLO thresholds. This is a challenge when bootstrap supplies are used for VHB. A floating bias supply such as an isolated supply or charge pump can be used to achieve 100% duty cycle operation.