ZHCSKL1A December 2019 – May 2022 TUSS4440
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| ICLAMP | Current clamping range | 50 | 500 | mA | ||
| ILIMIT_LOW | Minimum value on OUTA/OUTB during bursting for linear operation of current limit (headroom) | 2 | V | |||
| ICLAMP_ADJ | Current clamping adjustment steps | 64 | ||||