SLVSH99A December 2023 – August 2025 TPS22996
PRODUCTION DATA
The design in this example is trying to achieve 1000μs rise time for power sequencing, with both VBIAS and VIN to be 5V. From Table 8-1, the ION needs to be between 20μA and 100μA. To find the ION needed to achieve 1000μs rise time, linear interpolation can be used to estimate as below:
where:
ION is calculated to be 86.8μA. To find the RT value, plug in the parameters in Equation 1.
RT = 1000 × (5V ? 1.2V) / 86.8μA ? 11.5kΩ = 32.2kΩ
By using the standard resistor value closest to 32.2kΩ, the typical rise time can be calculated for the actual resistor value used on board.