| VBAT Over Voltage Fault | VBAT above limit | '100' PROTECTIVE SHUTDOWN with AUTO RECOVERY State | Apply VBAT within spec | Power Fault Status Register | Power Fault Memory Register |
| VBAT Under Voltage Fault | VBAT below limit | Apply VBAT within spec |
| PVDD Over Voltage Fault | PVDD above limit | Apply PVDD within spec |
| PVDD Under Voltage Fault | PVDD below limit | Apply PVDD within spec |
| GVDD Fault | GVDD regulator fault | |
| DVDD POR | DVDD voltage dropped below POR limit or initial device startup | '001' Hi-Z State | Write initial device configuration via I2C | N/A |
| Over Temperature SD - Channel | Channel temperature above limit | '101' PROTECTIVE SHUTDOWN State | Clear Fault | Temperature (OTSD) and Clock Sync Fault Status Register | Temperature (OTSD) and Clock Sync Fault Memory Register |
| Over Temperature SD - Global | Die temperature above limit |
| Over Current Shut Down (OCSD) Event | Short to ground or short to power | '101' PROTECTIVE SHUTDOWN State | Clear Fault | N/A | Channel Over Current and DC Detection Fault Memory Register |
| DC Fault Event | DC voltage at device input |
| Load Current Fault Event | Shorted load | Channel Load Current Fault Memory Register |
| Invalid Clock Fault Event | Missing clock signal while device set up as clock slave | '100' PROTECTIVE SHUTDOWN with AUTO RECOVERY State | Apply sync clock signal within nominal range | Temperature (OTSD) and Clock Sync Fault Status Register | Temperature (OTSD) and Clock Sync Fault Memory Register |
| If 'OTSD auto recovery' is enabled in Miscellaneous Control Register 3: |
| Over Temperature SD- Channel | Channel temperature above limit | '100'
PROTECTIVE SHUTDOWN with AUTO RECOVERY State | Cool down device | Temperature (OTSD) and Clock Sync Fault Status Register | Temperature (OTSD) and Clock Sync Fault Memory Register |
| Over Temperature SD - Global | Die temperature above limit |