ZHCSPL8B May 2023 – July 2024 TMUX4827
PRODUCTION DATA
| 參數 | 測試條件 | TA | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|---|
| 模擬開關 | |||||||
| RON | 導通電阻 | VDD = 2.5V 至 5.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.13 | 0.16 | Ω | |
| -40°C 至 +85°C | 0.225 | Ω | |||||
| -40°C 至 +125°C | 0.250 | Ω | |||||
| RON | 導通電阻 | VDD = 1.8V 至 2.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.19 | 0.22 | Ω | |
| -40°C 至 +85°C | 0.25 | Ω | |||||
| -40°C 至 +125°C | 0.3 | Ω | |||||
| ΔRON | 通道間的導通電阻不匹配 | VDD = 2.5V 至 5.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.002 | 0.03 | Ω | |
| -40°C 至 +85°C | 0.03 | Ω | |||||
| -40°C 至 +125°C | 0.05 | Ω | |||||
| ΔRON | 通道間的導通電阻不匹配 | VDD = 1.8V 至 2.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.003 | 0.035 | Ω | |
| -40°C 至 +85°C | 0.04 | Ω | |||||
| -40°C 至 +125°C | 0.06 | Ω | |||||
| RON FLAT | 導通電阻平坦度 | VDD = 2.5V 至 5.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.001 | 0.01 | Ω | |
| -40°C 至 +85°C | 0.05 | Ω | |||||
| -40°C 至 +125°C | 0.07 | Ω | |||||
| RON FLAT | 導通電阻平坦度 | VDD = 1.8V 至 2.5V VS = –12V 至 +12V ID = –100mA |
25°C | 0.003 | 0.015 | Ω | |
| -40°C 至 +85°C | 0.07 | Ω | |||||
| -40°C 至 +125°C | 0.09 | Ω | |||||
| RON DRIFT | 導通電阻漂移 | VS = 0V,IS = –100mA | -40°C 至 +125°C | 0.001 | ?/°C | ||
| IS(OFF) | 源極關斷漏電流(1) | 開關狀態為關 VS = ±12V/0V VD = 0V/±12V |
25°C | 0.02 | uA | ||
| -40°C 至 +85°C | -0.1 | 0.1 | uA | ||||
| -40°C 至 +125°C | -1 | 1 | uA | ||||
| IS(ON) ID(ON) |
通道導通漏電流(2) | 開關狀態為開 VS = VD = ±12V |
25°C | 0.02 | uA | ||
| -40°C 至 +85°C | -0.1 | 0.1 | uA | ||||
| -40°C 至 +125°C | -1 | 1 | uA | ||||
| IS(POFF) | 源極關斷漏電流(1) | VDD = 0V VS = ±12V/0V VD = 0V/±12V |
25°C | 0.02 | uA | ||
| -40°C 至 +85°C | -0.1 | 0.1 | uA | ||||
| -40°C 至 +125°C | -2 | 2 | uA | ||||
| ID(POFF) | 漏極關斷漏電流(1) | VDD = 0V VS = ±12V/0V VD = 0V/±12V |
25°C | 0.02 | uA | ||
| -40°C 至 +85°C | -0.1 | 0.1 | uA | ||||
| -40°C 至 +125°C | -2 | 2 | uA | ||||
| 邏輯輸入(SEL/EN 引腳) | |||||||
| VIH | 邏輯電壓高電平 | -40°C 至 +125°C | 1.1 | 5.5 | V | ||
| VIL | 邏輯電壓低電平 | -40°C 至 +125°C | 0 | 0.6 | V | ||
| IIH | 輸入漏電流 | -40°C 至 +125°C | 1 | 80 | nA | ||
| IIL | 輸入漏電流 | -40°C 至 +125°C | -10 | -1 | nA | ||
| CIN | 邏輯輸入電容 | -40°C 至 +125°C | 5 | pF | |||
| 電源 | |||||||
| IDD | VDD 電源電流 | 邏輯輸入 = 0V、5V 或 VDD | 25°C | 55 | 125 | μA | |
| -40°C 至 +85°C | 130 | μA | |||||
| -40°C 至 +125°C | 140 | μA | |||||