over operating free-air temperature range (unless
otherwise noted) (1)
|
MIN |
MAX |
UNIT |
| VCC |
Supply voltage |
–0.5 |
4 |
V |
| VI |
Input voltage(2) |
–0.5 |
4 |
V |
| II |
Input current |
–20 |
20 |
mA |
| IO |
Output current |
–25 |
25 |
mA |
| ICC |
Supply current |
–100 |
100 |
mA |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
| Tamb |
Ambient Temperature |
Ambient Temperature |
-40 |
125 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress ratings only, which do
not imply functional operation of the device at these or any other conditions beyond
those indicated under Recommended Operating Conditions. Exposure to
absolute-maximum-rated conditions for extended periods may affect device
reliability.
(2) The input negative-voltage and output voltage ratings may be
exceeded if the input and output current ratings are observed.