over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
NOM |
MAX |
UNIT |
| Input Pins |
A to GND |
–60 |
|
65 |
V |
| C to GND |
|
|
65 |
| EN to GND |
–60 |
|
65 |
| External capacitance |
A |
0.1 |
|
|
μF |
| VS, CAP to C |
1 |
|
|
μF |
| External Inductor |
LX |
100 |
|
|
μH |
| External MOSFET max VGS rating |
GATE to A |
15 |
|
|
V |
| TJ |
Operating junction temperature range(2) |
–40 |
|
150 |
°C |
(1) Recommended Operating Conditions are conditions under which the device
is intended to be functional. For specifications and test
conditions, see
Electrical Characteristics.
(2) High junction temperatures degrade operating lifetimes. Operating lifetime is de-rated for junction temperatures greater than 125°C.