4 修訂歷史記錄
Changes from B Revision (February 2016) to C Revision
-
Deleted REG 0x02 from the test conditions of the Ioso1 and Iosi1 parameters in the Electrical Characteristics table Go
-
Changed the value of R1 + R2 ≥ 100 KΩ to R1 + R2 ≥ 1 KΩ in the OC_ADJ section.Go
Changes from A Revision (December 2015) to B Revision
-
Changed VEN_BUCK in Buck Converter Characteristics From: MIN = 0.9 V and MAX = 1.55 V To: MIN = 1.11 V and MAX = 1.36 V. Go
Changes from * Revision (August 2011) to A Revision
-
Added 引腳配置和功能部分,ESD 額定值表,特性 描述 部分,器件功能模式,應用和實施部分,電源相關建議部分,布局部分,器件和文檔支持部分以及機械、封裝和可訂購信息部分Go
-
VPVDD absolute max voltage rating reduced from 70 V to 65 V Go
-
Clarification made on how the OCP status bits report in Overcurrent Protection (OCP) and Reporting Go
-
Update to PVDD1 undervoltage protection in Undervoltage Protection (UVLO) describing specific transient brownout issue. Go
-
Update to EN_GATE pin functional description in EN_GATE clarifying proper EN_GATE reset pulse lengths. Go
-
Added gate driver power-up sequencing errata Gate Driver Power Up Sequencing ErrdataGo
-
Added Community Resources Go