ZHCSPC2C September 2021 – January 2023 BQ25180
PRODUCTION DATA
The BQ25180 has four main modes of operation: Battery Mode, Ship Mode, Charge/Adapter Mode when a supply is connected to IN, and Shutdown mode. The table below summarizes the functions that are active for each operation mode.
|
FUNCTION |
CHARGE/ADAPTER MODE |
BATTERY MODE |
SHIP MODE |
SHUTDOWN MODE |
|---|---|---|---|---|
| Input overvoltage |
Yes |
Yes |
No |
No |
|
Input undervoltage |
Yes |
Yes |
Yes |
Yes |
|
Battery overcurrent |
Yes, if enabled |
Yes |
Yes, if enabled |
No |
| Battery undervoltage |
Yes |
Yes |
No |
No |
|
Input DPM |
Yes, if enabled |
No |
No |
No |
|
Dynamic power path management |
Yes, if enabled |
No |
No |
No |
|
BATFET |
Yes |
Yes |
No |
No |
|
TS measurement |
Yes |
No |
No |
No |
|
Battery charging |
Yes, if enabled |
No |
No |
No |
|
ILIM |
Yes (Register Value) |
No |
No |
No |
| Pushbutton input |
Yes |
Yes, if enabled |
Yes |
No |
|
INT output |
Yes |
Yes |
No |
No |
|
I2C |
Yes |
Yes |
No |
No |