SLUUCC3 february 2021 BQ79631-Q1
The following table identifies the key electrical parameters:
| Parameter | Value |
|---|---|
| Maximum battery pack voltage (stacked EVMs) | 2400 V |
| Maximum operating voltage | 80 V (depends on series R3, R4 value) |
| Minimum operating voltage | 9 V (depends on series R3, R4 value, by default use at least 18V) |
| Maximum cell open circuit voltage | 5 V |
| Ambient temperature | –40 °C to 105 °C |
| Nominal operating temperature | –20 °C to 60 °C |
| Cell balancing current | Approximately 200 mA @ 80 °C |