SFFSA42A December 2024 – May 2025 UCC33020 , UCC33020-Q1 , UCC33410 , UCC33410-Q1 , UCC33420 , UCC33420-Q1
The failure mode distribution estimation for the UCC33010, UCC33010-Q1, UCC33020, UCC33020-Q1, UCC33410, UCC33410-Q1, UCC33420, UCC33420-Q1 in Table 3-1 comes from the combination of common failure modes listed in standards such as IEC 61508 and ISO 26262, the ratio of sub-circuit function size and complexity, and from best engineering judgment.
The failure modes listed in this section reflect random failure events and do not include failures resulting from misuse or overstress.
| Die Failure Modes | Failure Mode Distribution (%) |
|---|---|
| VCC has no power | 38 |
| VCC accuracy and ripple not meeting specifications | 30 |
| FAULT reporting not working | 14 |
| No effect | 18 |
The FMD in Table 3-1 excludes short-circuit faults across the isolation barrier. Faults for short circuits across the isolation barrier can be excluded according to IEC 61800-5-1 if the following requirements are fulfilled:
Apply creepage and clearance requirements according to the specific equipment isolation standards of an application. Care must be taken to maintain the creepage and clearance distance of a board design to make sure that the mounting pads of the isolator on the printed-circuit board do not reduce this distance.