SFFSA01 September 2024 LM70660 , LM706A0
This section provides functional safety failure in time (FIT) rates for LM706A0 and LM70660 based on two different industry-wide used reliability standards:
| FIT IEC TR 62380 / ISO 26262 | FIT (Failures Per 109 Hours) | |
|---|---|---|
| LM706A0 | LM70660 | |
| Total component FIT rate | 40 | 27 |
| Die FIT rate | 16 | 6 |
| Package FIT rate | 24 | 21 |
The failure rate and mission profile information in Table 2-1 comes from the reliability data handbook IEC TR 62380 / ISO 26262 part 11:
| Table | Category | Device | Reference FIT Rate | Reference Virtual TJ |
|---|---|---|---|---|
| 5 | CMOS, BICMOS ASICs Analog and mixed HV > 50V supply | LM706A0 | 30 FIT | 75°C |
| 5 | CMOS, BICMOS ASICs Analog and mixed HV > 50V supply | LM70660 | 30 FIT | 75°C |
The reference FIT rate and reference virtual TJ (junction temperature) in Table 2-2 come from the Siemens Norm SN 29500-2 tables 1 through 5. Failure rates under operating conditions are calculated from the reference failure rate and virtual junction temperature using conversion information in SN 29500-2 section 4.