SFFS339A December 2022 – August 2025 TLIN1431-Q1
Table 3-1 provides estimates of FIT rates and calculated safety metrics per ISO 26262-5:2018 using previously noted assumptions for the device.
| Die | Package | Overall | ||||
|---|---|---|---|---|---|---|
| Permanent | Transient | Permanent | Sum | |||
| Total FIT (Raw FIT) | λ | 3.29 | 0.00 | 14.59 | 17.88 | |
| Safety Related FIT | λSR | 3.29 | 0.00 | 14.59 | 17.88 | |
| Probabilistic Metrics for Random Hardware Failures (in FIT) | PMHF | 1.17 | 0.00 | 2.27 | 3.44 | |
| Single Point Fault Metric | SPFM | 64.55 | 0.00 | 84.43 | 80.77 | |
| Latent Fault Metric | LFM | 89.77 | N/A | 87.30 | 87.66 | |